Provide
maximum security
with
open air benefits for stored turnout gear. |
GEARMASTERS Air-Flow Lockers
come in four sizes. One, two, three and four section combinations
are available. Each firefighter's locker has interior dimensions of
18" width, 21" depth and 72" height. Lockers are painted with a light
gray enamel, with several other colors available, and each has a stainless
steel recessed handle that can accommodate your own padlock. 18" wide
doors are one piece, full width. Standard locker construction is flat
top with 6" legs. The rear legs are adjustable to compensate for uneven
floors. Base enclosure panels are an option. Lockers can be furnished
without legs for curb or wall mounting installations. |
Model
|
Dimensions
|
Capacity
|
| VSL-1
|
18"w
x 21"d x 78"ht. |
1
Section |
| VSL-2
|
36"w
x 21"d x 78"ht. |
2
Section |
| VSL-3
|
54"w
x 21"d x 78"ht. |
3
Section |
| VSL-4
|
72"w
x 21"d x 78"ht. |
4
Section |
These
models are available through GSA Contract #
GS-28F-8053H |
|
GEARMASTERS
Air-Flow Lockers are shipped "knocked down" for field assembly. Detailed
instructions are provided. A 3/8" socket driver is the only tool required.
Each locker section is provided with a 6" plastic name tag holder
and one Air-dry Coat Hanger |
|
GEARMASTERS Air-Flow Lockers
are designed for fire service applications that require a high degree
of ventilation and strength, or where visible inspection of locker
contents is desired. These are ideal for career personnel to secure
their turnout gear and belongings when off duty. The doors are made
from 14 gauge steel, the backs of 18 gauge. A diamond shaped pattern
in the doors and sides permits maximum air circulation around the
fire gear, thus enhancing the drying time and dissipation of smoky
odors. |
|
|
|

MATERIAL: All parts made from cold rolled sheet steel, free from surface
imperfection, and capable of taking a high grade enamel finish.
FINISH:
All parts to be thoroughly cleaned before painting and given a bonding
and rust resisting phosphate coating to inhibit corrosion, followed
by one coat of high grade enamel sprayed on by electrostatic method.
All locker parts shall be sprayed inside and outside with the same
color. Enamel to be baked on with the proper temperature/time relationship
to insure thorough curing and a tough, durable finish. Standard color
to be light gray. Additional colors available upon request. Hardware
to be cadmium plated #10-24 truss fin head bolts and hex nuts.
DOOR FRAME: All door frame members to be not less than 16 gauge formed
to a channel shape. Vertical members to have an additional flange
to provide a continuous door strike. Cross frame members of 16 gauge
channel shapes shall be securely welded to vertical framing members
to insure rigidity.
DOORS: Doors shall be formed of one piece 14 gauge cold rolled sheet
steel. Formations shall consist of a full channel shape on the lock
side of adequate depth to fully conceal the lock bar, channel on the
hinge side and right angle formations across the top and bottom. Doors
shall be perforated for free air flow while leaving sufficient metal
for door strength and rigidity utilizing diamond shaped perforations
3/4" X 1-1/2".
DOOR HANDLE: Handles shall be completely recessed in the door and
be finger lift control. The formed pocket shall be brushed stainless
steel, securely fastened to the door with two lugs plus a positive
tamper resistant decorative fastener. The pocket shall be of sufficient
depth to prevent a combination padlock from protruding beyond the
face of the door. A lock hole cover plate shall be provided for the
use with padlocks. The lifting piece shall be 14 gauge formed steel,
attached to the latching channel with one concealed retaining lug
and one rivet assuring a positive two point connection. It shall have
a sound deadening molded finger lift attached with a rivet.
LATCHING: Doors to have a latch clip engaging the door frame at three
points. Locking device shall be positive, automatic type. One rubber
silencer shall be provided at each latch hook and shall be firmly
secured in the frame and retained by the latch hook. Latch hook to
have a bevel on front upper edge to allow latch clip to ride up slope
as door is closed. Latch hooks shall have tamper guards.
HINGES: .050" thick, double spun, full loop, tight pin fiveknuckle
hinges with double wrapped leaves, 2" high projection welded to door
frame and securely fastened to the door with two rivets. Each locker
door to have three hinges.
CONSTRUCTION: Built on the unit principal, each locker shall have
an individual door and frame, individual top, bottom, interior shelf
and common intermediate uprights separating compartments.
BODY: Bolt spacing in locker body construction not to exceed 9" o.c.
All locker body components shall be made of cold rolled steel specially
formed for added strength and rigidity and to insure tight joints
at fastening points. Locker side panels shall be 16 gauge cold rolled
sheet steel perforated with diamond shaped openings 3/4" X 1-1/2"
high in such quantity and pattern as to insure maximum ventilation.
Locker backs shall be formed from 18 gauge cold rolled sheet steel
with right angle flanges on each vertical side for stiffness, ease
of assembly, and to provide corner rigidity to the locker unit. Tops,
bottoms and helmet storage shelf shall be formed from 16 gauge cold
rolled steel fully flanged on all sides for added stiffness. The helmet
shelf shall have an additional return flange on the front edge creating
a channel shape to rigidize the impact surface.
INTERIOR EQUIPMENT: Lockers to have a helmet shelf located approximately
12" below top of locker. Coat hanger rod to be 18" wide and bolts
to each side along with a single prong wall utility hook. Two additional
utility hooks are provided for mounting on interior of locker rear
walls. |
|
| |