For the MSA and Draeger
INSTRUCTIONS
As soon as you recognize that you are lost or that your breathable air is compromised, immediately initiate a MAYDAY (request for help) by any means possible. Begin looking for potential sources of breathable air. Consider the trapped air that might be remaining within your turnout coat.
Remove the product from its stored location prior to the depletion of your air supply. Once the SCBA has been depleted, remove the mask mounted regulator and replace it with the MAYDAY-Air. The MAYDAY-Air must be inserted fully into the SCBA face piece and then rotated a 1/4 turn to ensure a proper seal. For MSA: slide to connect, push to connect and quarter turn. Direct the breathing hose towards the selected air source and begin breathing.
DANGER
Failure to familiarize yourself in advance with how the MAYDAY-Air product
attaches to the face piece could result in death or serious injury.
This product is designed for use in smoke-filled atmospheres only and shall
only be used when no other option exists for the firefighter.
This product should never be used as a substitute for a properly
functioning SCBA.
WARNING
This product does not ensure a fresh air supply will be established.
This product does not keep you from inhaling smoke or other fire gases.
This product does not guarantee your survival.
The breathing tube will kink. Store in a manner that avoids kinking
For Scott
INSTRUCTIONS
As soon as you recognize that you are lost or that your breathable air supply is compromised, immediately initiate a MAYDAY (request for help) by any means possible. Begin looking for potential sources of breathable air. Consider the trapped air that might be remaining within your turnout coat.
Step 1:
Remove the MAYDAY Puck from its stored location and fully insert one end of the breathing tube into the label side of the Puck.
Step 2:
Once the SCBA air supply becomes depleted, remove the mask mounted regulator from the SCBA face piece and replace it with the Puck. Fully insert the Puck into the face piece inlet and rotate the Puck a 1/4 turn to ensure a proper seal.
Step 3:
Direct the other end of the breathing tube towards the selected air source and begin breathing.
DANGER
Failure to familiarize yourself in advance with how the MAYDAY-Air product
attaches to the face piece could result in death or serious injury.
This product is designed for use in smoke-filled atmospheres only and shall
only be used when no other option exists for the firefighter.
This product should never be used as a substitute for a properly
functioning SCBA.
WARNING
This product does not ensure a fresh air supply will be established.
This product does not keep you from inhaling smoke or other fire gases.
This product does not guarantee your survival.
The breathing tube will kink. Store in a manner that avoids kinking.