$164.39
List: $177.77 |Save: $13.38

Honeywell PBI Lenzing Particulate Resistant Hood

SKU: HD-PLPR//IN STOCK, ORDER NOW!

Details

Comfort and protection a compromise? NOT ANYMORE!

STEDFAST Inc. introduces a highly breathable, air permeable, flexible and flame resistant material offering superior particulate blocking performance. Stedair PREVENT, consists of a composite barrier made from Stedair moisture barriers proprietary technology.

Firefighters neck and head areas are vulnerably exposed and highly sensitive to concentrations of toxic chemicals and permeation to the skin. Average hoods' offer a limited protection against these toxic particles. Stedair PREVENT offers oustanding breathability, increased air permeability and a unique construction for ease of movement and flexibility. These combined properties also enable Stedair PREVENT to minimize heat stress.

Stedair PREVENT when tested accordingly to NFPA 1971 not only meets the required 90% blocking efficiency but surpasses with results of 99.99% blocking efficiency with maginal loss after extreme conditioning against particle size.
 
 Test NameNFPA 1971
Performance
Requirement
Paragraph
Test MethodSpecificationStedair PreventComment
Protection*TPP7.13.2, par. 8.10ISO 17492> 20.025Meets & Exceeds
Flame Resistance7.13.3, par. 8.2ASTM D 6413< 100 mm Char,
< 2-sec Burn, No Melt, No Drip
0.0 s; 85 mm (L)
0.0 s; 77 mm (W)
Meets & Exceeds
Heat and Thermal Shrinking7.1.4 and 7.1.5, par. 8.6ISO 17493< 10%, No Melt,
Seperation or Ignition
5.2% (L)
6.8% (W)
Meets & Exceeds
*Particulate Blocking Test INITIAL7.14.2, par. 8.71ASTM F2299Particulate Efficiency > 90% (0.1-1.0 micron)> 99.99%
(0.1-1.0 micron)
-
 Test NameNFPA 1971
Performance
Requirement
Paragraph
Test MethodSpecificationStedair PreventComment
ComfortTHL7.14.3, par 8.33ASTM F1868
Part C
< 352 W/m2704 W/m2-
*THL7.14.3, par 8.33ASTM F1868
Part C
< 352 W/m2427 W/m2Meets & Exceeds
Air PermeabilityNot RequiredASTM D737
(Fraizer Air Perm.)
Not Required10 CFM-
 Test NameNFPA 1971
Performance
Requirement
Paragraph
Test MethodSpecificationStedair PreventComment
DurabiltyBursting Strength7.13.8, par 8.13ASTM D6797> 225 N (51 lbf) individual layers550 NMeets & Exceeds
*Particulate Blocking Test after 2x conditioning7.14.2, 8.1.2 (2x) 8.1.3, 8.1.5AATCC 135 method 1, v, Ai
ASTM D1776
Particulate efficiency
> 90% (0.1-1.0 micron)
> 99.99%
(0.1-1.0 micron)
Meets & Exceeds
*when tested with one layer of 8oz/yd2 Nomex knit
  • 99.99% BLOCKING EFFICIENCY
  • AFTER 100 WASH/DRY CYCLES
  • HIGHLY AIR PERMEABLE
  • SUPERB DURABILITY
  • THE HIGHEST THL IN THE INDUSTRY
  • SUPERIOR PARTICULATE BLOCKING PERFORMANCE
THL - The higher the better
THL is the only property recognized by NFPA 1971-2018 for protecting firefighters from heat stress

Ratings & Reviews

1 review

  • 4 stars
  • 0 reviews
  • 3 stars
  • 0 reviews
  • 2 stars
  • 0 reviews
  • 1 star
  • 0 reviews

Positive Experience

by

Have had this hood for 6 months or so now and love it. Very comfortable, performs well and ticks all the boxes. Highly recommended 👌🏻